Facebook
  • 12.8V 18Ah LiFePO4 4S10P battery pack product illustration - 18650 4S10P M5
  • 12.8V 18Ah LiFePO4 4S10P battery pack product illustration - 18650 4S10P M5

12.8V 18Ah Custom LiFePO4 Battery Pack | 18650 4S10P M5

No.SL-LFP-12.8V-18AH-4S10P-M5

12.8V 18Ah custom LiFePO4 battery pack with 18650 4S10P cells, approximately 230.4Wh nominal energy. 18650 4S10P M5 configuration for OEM integration.

  • 12.8V 18Ah LiFePO4 4S10P battery pack product illustration - 18650 4S10P M5

Description

A 12.8V 18Ah Pack: 18650 4S10P M5

This 12.8V 18Ah custom LiFePO4 battery pack uses 18650 cells in a 4S10P arrangement, providing approximately 230.4Wh nominal energy. Positive and negative M5 terminal holes.

Body dimensions are (181 ± 2) × (76.5 ± 1) × (168 ± 3)mm, with a reference weight of 2.3 ± 0.1kg. The product illustration is a configuration reference; allow clearance for leads, connectors and mounting hardware.

Datasheet Values for the 12.8V 18Ah Build

Parameter Specification
Surlon website model SL-LFP-12.8V-18AH-4S10P-M5
Chemistry / cell arrangement LiFePO4 / 18650 4S10P
Nominal voltage 12.8V
Rated / minimum capacity 18Ah / 17Ah at C5
Nominal energy Approximately 230.4Wh
Internal resistance ≤50mΩ
Body dimensions (181 ± 2) × (76.5 ± 1) × (168 ± 3)mm
Weight 2.3 ± 0.1kg
Shell material Plastic
Charging voltage 14.4 ± 0.15V
Charging current ≤3.6A
Charge cut-off current 180-360mA
Discharge cut-off voltage Approximately 10.0V
Discharge current 15A normal; 15-20A for ≤5 minutes
Power interface Positive and negative M5 terminal holes.
Protection functions Overcharge, over-discharge and temperature protection; balancing
Charging temperature 0°C to 45°C
Discharging temperature -20°C to 60°C
Cycle life ≥2000 cycles with ≥80% retained capacity under the specified standard test
Charge retention ≥80% after 28 days under the specified standard test

Electrical Strengths of the 4S10P Build

  • 18Ah rated capacity and approximately 230.4Wh nominal energy.
  • Defined discharge profile: 15A normal; 15-20A for ≤5 minutes.
  • 14.4 ± 0.15V charging voltage, with current ≤3.6A.
  • Positive and negative M5 terminal holes.

How This Build Differs from Its Siblings

Match capacity, enclosure dimensions, cell arrangement and load duration when selecting a 12.8V pack. M5, M6, M8, Φ5.5 terminals and separate charging sockets require different mating hardware; a matching nominal voltage alone does not establish compatibility.

Explore the Custom LiFePO4 Battery Packs range for related configurations.

Duty, Charge and Temperature Limits

  • Charge at 14.4 ± 0.15V with current ≤3.6A. Charge cut-off current: 180-360mA.
  • Discharge specification: 15A normal; 15-20A for ≤5 minutes. A connector current designation does not change the pack current rating. Preserve the duration of every higher-current allowance.
  • Charge from 0°C to 45°C; discharge from -20°C to 60°C. Provide ventilation and heat dissipation above 45°C; avoid condensation and keep ambient relative humidity ≤85%.
  • Cycle life: ≥2000 cycles with ≥80% retained capacity. Standard testing uses 25 ± 2°C and 65 ± 20% RH, CC/CV charging at I5 to 0.05 I5, discharge at I5 to approximately 10.0V or pack cut-off, and 0.5-1 hour rest after charge and discharge. If I5 exceeds normal operating current, use normal operating current.
  • Store dry at 0°C to 40°C, preferably 15°C to 25°C. Do not connect complete packs in series or parallel.

Connecting the Specified Power Interface

Positive and negative M5 terminal holes.

  1. Verify the approved drawing, polarity and mating interface before connection.
  2. Match charger settings and the equipment input voltage range to this pack.
  3. Secure the enclosure and provide lead clearance and strain relief.
  4. Confirm the approved terminal drawing, polarity and fastening requirements before connecting the equipment.

Devices That Match This Discharge Profile

Potential applications include OEM DC equipment, control systems and monitoring assemblies designed for the specified voltage window. Suitability depends on the actual load, runtime target, enclosure fit and interface compatibility. Validate the pack in the intended equipment before production approval.

Technical Support & Model Matching

Quote website model SL-LFP-12.8V-18AH-4S10P-M5 and provide the load profile, compartment drawing, charger specification and host interface requirements to Surlon Power. Confirm the final configuration and sample performance before ordering.

FAQ

What is the Surlon website model?

SL-LFP-12.8V-18AH-4S10P-M5 identifies this 12.8V 18Ah 18650 4S10P M5 configuration.

What charging limits apply?

14.4 ± 0.15V; current ≤3.6A; charge cut-off current 180-360mA; charging temperature 0°C to 45°C.

What is the discharge-current limit?

15A normal; 15-20A for ≤5 minutes. Keep every higher-current interval within its stated duration.

Which power interfaces should be matched?

Positive and negative M5 terminal holes.

How is cycle life specified?

At least 2000 cycles with at least 80% retained capacity under the specified standard charge/discharge test, including its current, temperature and 0.5-1 hour rest conditions.

Download

REQUEST A BATTERY QUOTE

Tell us about your equipment and battery requirements. Share the details you know, and our team can discuss the next steps for your project.
Name
Email *
Message
Leave a message
Name
Email *
Message
Message Us